r4706
Measuring function, status / Meas fct status
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: Integer16
CU_S110-PN
P-Group: Trace and function generator
Not for motor type: -
Min
0
Description:
Displays the actual status of the measuring function.
Value:
0:
1:
2:
3:
4:
5:
p4707
Measurement function configuration / Meas fct config
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Integer16
CU_S110-PN
P-Group: -
Not for motor type: -
Min
0
Description:
Setting to configure the measurement function.
Value:
0:
1:
Note:
The parameter cannot be changed when the measurement function has been started (r4706 = 2, 3).
For value = 0:
The system injection point selected to inject the function generator signal is used.
For value = 1:
No system injection point is used.
When using the measuring function in the STARTER commissioning software, the following applies:
A change to a value only becomes effective after first closing and opening the measuring function screen form.
For value = 0:
The master control must be fetched.
There are two fixed and two freely selectable signals for recording.
For value = 1:
Master control does not have to be fetched.
There are four freely selectable signals for recording.
r4708[0...1]
Trace memory space required / Trace mem required
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: Unsigned32
CU_S110-PN
P-Group: Trace and function generator
Not for motor type: -
Min
-
Description:
Displays the required memory in bytes for the actual parameterization.
Index:
[0] = Trace 0
[1] = Trace 1
Dependency:
Refer to: r4799
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Measurement function inactive
Measuring function, parameterization checked
Measuring function waits for stabilizing time
Measuring function recording (tracing)
Measuring function, trace ended with error
Measuring function, trace successfully completed
Standard
Free meas fct
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
5
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
1
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Parameter
List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
1-451