p9484
BICO interconnections search signal source / BICO S_src srch
All objects
Can be changed: T
Data type: Unsigned32
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the signal source (BO/CO parameter, BICO coded) to search in the signal sinks.
The question is answered:
How often is a connection made to a signal source in the drive object and from which index are these interconnec-
tions saved (r9482 and r9483)?
Dependency:
Refer to: r9481, r9482, r9483, r9485, r9486
r9485
BICO interconnections signal source search count / BICO S_src srchQty
All objects
Can be changed: -
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the number of BICO interconnections to the signal sink being searched for.
Dependency:
Refer to: r9481, r9482, r9483, p9484, r9486
Note:
The signal source to be searched is set in p9484 (BICO-coded).
The search result is contained in r9482 and r9483 and is specified by the count (r9485) and the first index (r9486).
r9486
BICO interconnections signal source search first index / BICO S_src srchIdx
All objects
Can be changed: -
Data type: Unsigned16
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the first index of the signal source being searched for.
Dependency:
Refer to: r9481, r9482, r9483, p9484, r9485
Note:
The signal source to be searched is set in p9484 (BICO-coded).
The search result is contained in r9482 and r9483 and is specified by the count (r9485) and the first index (r9486).
p9500
SI Motion monitoring clock cycle (processor 1) / SI Mtn clock P1
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
0.50 [ms]
Description:
Sets the monitoring clock cycle for safe motion monitoring.
Dependency:
Refer to: r2064, p9511
Refer to: F01652
Note:
A change only becomes effective after a POWER ON.
The monitoring clock cycle must be a multiple of the actual value sensing clock cycle in p9511 (dbSI) or of the DP
clock cycle (ncSI).
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
4294967295
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
25.00 [ms]
Parameter
List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
12.00 [ms]