Siemens SINAMICS S110 List Manual page 480

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
Index:
[0] = Reference firmware version
[1] = Actual firmware version
[2] = EPROM0 version
[3] = EPROM1 version
[4] = EPROM2 version
[5] = EPROM3 version
[6] = EPROM4 version
Note:
Reference firmware version: Version on the memory card/device memory.
Current firmware version: Actual version of the DRIVE-CLiQ component.
EPROM version: Current EPROM version of the DRIVE-CLiQ component.
r7827
Firmware update progress display / FW update progress
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: FloatingPoint32
CU_S110-PN
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Displays the progress when updating the firmware of the DRIVE-CLiQ components.
p7830
Diagnostics telegram selection / Diag telegram
SERVO_S110-CAN,
Can be changed: T
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: -
Not for motor type: -
Min
0
Description:
Selects a telegram whose contents should be shown in p7831 ... p7836.
Value:
0:
1:
2:
3:
Dependency:
Refer to: r7831, r7832, r7833, r7834, r7835, r7836
r7831[0...15]
Telegram diagnostics signals / Tel diag signals
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: -
Not for motor type: -
Min
0
Description:
Displays the signals contained in the selected telegram (p7830).
Value:
0:
1:
102:
110:
111:
112:
113:
114:
115:
10500: ENC_ID_TIME_PRETRIGGER
10501: ENC_ID_TIME_SEND_TELEG_1
10502: ENC_ID_TIME_CYCLE_FINISHED
10503: ENC_ID_TIME_DELTA_FUNMAN
10504: ENC_ID_SUBTRACE_CALCTIMES
1-480
Reserved
First cyclic receive telegram sensor 1
First cyclic receive telegram sensor 2
First cyclic receive telegram sensor 3
UNUSED
UNKNOWN
SAPAR_ID_DSA_ALARM
SAPAR_ALARMBITS_FLOAT_0
SAPAR_ALARMBITS_FLOAT_1
SAPAR_ALARMBITS_FLOAT_2
SAPAR_ALARMBITS_FLOAT_3
SAPAR_ALARMBITS_FLOAT_4
SAPAR_ALARMBITS_FLOAT_5
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
- [%]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
15157
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents