Siemens SINAMICS S110 List Manual page 470

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
p4800
Function generator control / FG control
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Integer16
CU_S110-PN
P-Group: Trace and function generator
Not for motor type: -
Min
0
Description:
The function generator is started with p4800 = 1.
The signal is only generated for a 1 signal of binector input p4819.
Value:
0:
1:
2:
3:
Dependency:
Refer to: p4819
r4805
Function generator status / FG status
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: Integer16
CU_S110-PN
P-Group: Trace and function generator
Not for motor type: -
Min
0
Description:
Displays the actual status of the function generator.
Value:
0:
1:
2:
3:
4:
5:
6:
Dependency:
Refer to: p4800, p4819
r4806.0
BO: Function generator status signal / FG status signal
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: Unsigned32
CU_S110-PN
P-Group: Trace and function generator
Not for motor type: -
Min
-
Description:
Displays the status of the function generator.
0 signal: Function generator inactive
1 signal: Function generator running
Bit field:
Bit
Signal name
00
Bit 0
p4810
Function generator mode / FG operating mode
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Integer16
CU_S110-PN
P-Group: Trace and function generator
Not for motor type: -
Min
0
Description:
Sets the operating mode of the function generator.
1-470
Stop function generator
Start function generator
Check function generator parameterization
Start function generator without enable signals
Inactive
Generate accelerating ramp to offset
Generate parameterized signal shape
Generate braking ramp
Function generator stopped due to missing enable signals
Function generator waits for BI: p4819
Function generator parameterization has been checked
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
6
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
ON
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
99
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
0 signal
FP
OFF
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0