Siemens SINAMICS S110 List Manual page 435

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Bit field:
Bit
Signal name
00
Motor/control parameters calculated (p0340
= 1, p3900 > 0)
02
Motor data identification carried out at
standstill (p1910 = 1)
03
Rotating measurement carried out (p1960 =
1, 2)
04
Motor encoder adjustment carried out
(p1960 = 1, p1990 = 1)
05
Motor encoder manually adjusted
15
Motor equivalent circuit diagram parameters
changed
Note:
The individual bits are only set if the appropriate action has been initiated and successfully completed.
When motor rating plate parameters are changed, the final display is reset.
When setting the individual bits, all of the most significant bits are reset.
r3927[0...n]
Motor data identification induction motor data determined / MotID ASM dat det
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: Motor identification
Not for motor type: -
Min
-
Description:
Displays the data of an induction motor determined and accepted from the stationary motor data identification or
rotating measurement.
Bit field:
Bit
Signal name
00
p0350 accepted
01
p0354 accepted
02
p0356 accepted
03
p0358 accepted
04
p0360 accepted
05
p0320 accepted
06
p0410 accepted
12
p1715 accepted
13
p1717 accepted
14
p1590 accepted
15
p1592 accepted
22
p0341 accepted
24
p0348 accepted
25
p1752 accepted
Dependency:
Refer to: r3925
r3928[0...n]
Motor data identification synchronous motor data determined / MotId PEM dat det
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: Motor identification
Not for motor type: REL
Min
-
Description:
Successfully completed component of the last rotating measurement carried out.
Bit field:
Bit
Signal name
00
p0350 accepted
02
p0356 accepted
06
p0410 accepted
07
p0431 accepted
08
p1952 accepted
09
p1953 accepted
12
p1715 accepted
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
1 signal
Yes
Yes
Yes
Yes
Yes
Changed
Calculated: CALC_MOD_ALL
Dynamic index: DDS, p0180
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: CALC_MOD_ALL
Dynamic index: DDS, p0180
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Parameter
List of parameters
0 signal
FP
No
-
No
-
No
-
No
-
No
-
Not changed
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
FP
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
FP
No
-
No
-
No
-
No
-
No
-
No
-
No
-
1-435

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents