Siemens SINAMICS S110 List Manual page 940

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

n_act smooth signal
r2169
[8010.2]
[8012.5]
[8013.1]
n_set for msg
p2151[C]
r1170
<2>
[3080.8]
n_set for msg
p2151[C]
r1438
[5210.4]
n_act 2
p2154[C]
<1> Applies only if the function module
"extended signals/monitoring functions" is active
(r0108.17 = 1).
<2> Evaluation only for:
Pulse enable and operating enable (r0899.2)
or OFF1
or OFF3
or rotating measurements
or friction characteristic plot.
1
2
DO: SERVO
Signals and monitoring functions - Speed signals 2
0
1
0
n_hysteresis 3
0.00...300.00 rpm
p2150[D] (2.00)
n_thresh val 4
0.00...210.000 rpm
p2163[D] (90.00)
+
1
Torque control active
0
+
r1407.2
[6060.3]
0
n_hysteresis 4
0.00...200.00 rpm
p2164[D] (2.00)
RFG active
p2148[C]
(0)
3
4
<1>
0
1
0
n_hysteresis 3
0.00...300.00 rpm
p2150[D] (2.00)
t_del_off n_i=n_se
0.0...500.0 ms
p2166[D] (200.0)
Speed setpoint actual value deviation in tolerance t_off
0
T
1
Enable alarm A07903
p2149.0[D]
1
t_on n_act=n_set
0.0...10 000.0 ms
1
p2167[D] (200.0)
0
Speed setpoint actual value deviation in tolerance t_on
T
0
1 = RESET
5
6
fp_8011_98_eng.vsd
30.09.11 V04.04.00
4000.00 μs
n_act
0
r2197.3
[2534.3]
n_set > 0
r2198.5
[2536.3]
n_thresh val 3
0.00...210000.00 rpm
p2161[D] (5.00)
1
|n_set|
p2161
r2198.4
[2536.3]
0
n_hysteresis 3
0.00...300.00 rpm
p2150[D] (2.00)
r2197.7
[2534.3]
A07903 "Motor speed deviation"
A07903 is only signaled for p2149.0 = 1 and r2197.7 = 0.
r2199.4
[2537.3]
Ramp-up/ramp-down completed
SET
Q
r2199.5
[2537.3]
(Q=1)
Priority
RESET
1 RESET
Q
(Q=0)
2 SET
7
8
Function diagram
- 8011 -
SINAMICS S110

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents