p9931[0...129]
System logbook module selection / SYSLOG mod select.
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Unsigned32
CU_S110-PN
P-Group: -
Not for motor type: -
Min
0000 hex
Description:
Only for service purposes.
p9932
Save system logbook EEPROM / SYSLOG EEPROM save
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Unsigned8
CU_S110-PN
P-Group: -
Not for motor type: -
Min
0
Description:
Only for service purposes.
r9975[0...7]
System utilization measured / Sys util meas
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: FloatingPoint32
CU_S110-PN
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Displays the measured system utilization.
The higher the value displayed, the higher the system utilization.
Index:
[0] = Computing time utilization (min)
[1] = Computing time utilization (averaged)
[2] = Computing time utilization (max)
[3] = Largest total utilization (min)
[4] = Largest total utilization (averaged)
[5] = Largest total utilization (max)
[6] = Reserved
[7] = Reserved
Dependency:
Refer to: r9976, r9979, r9980, r9981
Refer to: F01054, F01205
Note:
Re index 3 ... 5:
The total utilizations are determined using all sampling times used. The largest total utilizations are mapped here.
The sampling time with the largest total utilization is displayed in r9979.
Total utilization:
Computing time load of sampling time involved including load from higher-priority sampling times (interrupts).
r9976[0...7]
System utilization / Sys util
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: FloatingPoint32
CU_S110-PN
P-Group: -
Not for motor type: -
Min
- [%]
Description:
Displays the system utilization.
If the utilization is greater than 100%, fault F01054 is output.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
FFFF FFFF hex
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
255
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
- [%]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
- [%]
Parameter
List of parameters
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 hex
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [%]