p9920[0...99]
Licensing, enter license key / Enter license key
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Unsigned8
CU_S110-PN
P-Group: -
Not for motor type: -
Min
-
Description:
Enters the license key for this drive unit.
Example of the license key:
EACZ-QBCA = 69 65 67 90 45 81 66 67 65 dec (ASCII characters)
Index 0 = license key character 1 (e.g. 69 dec)
Index 1 = license key character 2 (e.g. 65 dec)
...
Index 8 = license key character 9 (e.g. 65 dec)
Index 9 = license key character 20 (e.g. 0 dec)
...
With the STARTER commissioning software, ASCII characters are not entered coded, i.e. the characters of the
license key can be entered as printed in the Certificate of License. In this case, STARTER codes the characters.
Dependency:
Refer to: r7843, p9921
Refer to: A13000, A13001, F13010
Notice:
An ASCII table (excerpt) can be found, for example, in the appendix to the List Manual.
Note:
If there is not a valid license key present, all the indices have the value 0 dec.
Only the ASCII characters, contained in a license key can be entered.
When changing p9920[x] to the value 0 dec, all the values of all the following indices are also set to 0 dec.
After entering the license key, the license key must be activated (p9921).
If the licensing is not adequate, then the following alarm is displayed together with LED:
- A13000 --> licensing not sufficient
- LED READY --> flashes green/red with 0.5 Hz
p9921
Licensing, activate license key / Act license key
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Integer16
CU_S110-PN
P-Group: -
Not for motor type: -
Min
0
Description:
Activates the entered license key.
The following is executed when activating the license key.
- the checksum of the entered license key is checked.
- the entered license key is saved in a non-volatile fashion on the memory card.
- re-enter the license key.
Value:
0:
1:
Dependency:
Refer to: p9920
Refer to: A13000, A13001, F13010
Note:
Before activation, the license key entered using parameter p9920 is checked. If this check identifies an error, acti-
vation is rejected. In this case, writing a 1 to p9921 is rejected.
When the license key has been activated, p9921 is automatically set to 0.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Inactive
Activate start license key
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
1
Parameter
List of parameters
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
1-615