Parameter
List of parameters
p20044
AND 3 run-time group / AND 3 RTG
CU_S110-CAN,
Can be changed: T
CU_S110-DP,
Data type: Integer16
CU_S110-PN,
P-Group: -
SERVO_S110-CAN
Not for motor type: -
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Min
0
Description:
Setting parameter for the run-time group in which the instance AND 3 of the AND function block is to be called.
Value:
0:
1:
2:
3:
4:
5:
6:
7:
8:
9:
9999: Do not calculate
p20045
AND 3 run sequence / AND 3 RunSeq
CU_S110-CAN,
Can be changed: T
CU_S110-DP,
Data type: Unsigned16
CU_S110-PN,
P-Group: -
SERVO_S110-CAN
Not for motor type: -
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Min
0
Description:
Setting parameter for the run sequence of instance AND 3 within the run-time group set in p20044.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20046[0...3]
BI: OR 0 inputs / OR 0 inputs
CU_S110-CAN,
Can be changed: T
CU_S110-DP,
Data type: Unsigned32 / Binary
CU_S110-PN,
P-Group: -
SERVO_S110-CAN
Not for motor type: -
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Min
-
Description:
Sets the signal source of input quantities I0, I1, I2, I3 of instance OR 0 of the OR function block.
Index:
[0] = Input I0
[1] = Input I1
[2] = Input I2
[3] = Input I3
1-656
Run-time group 0
Run-time group 1
Run-time group 2
Run-time group 3
Run-time group 4
Run-time group 5
Run-time group 6
Run-time group 7
Run-time group 8
Run-time group 9
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
9999
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
32000
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 1
Func. diagram: 7210
Unit selection: -
Expert list: 1
Factory setting
9999
Access level: 1
Func. diagram: 7210
Unit selection: -
Expert list: 1
Factory setting
40
Access level: 1
Func. diagram: 7212
Unit selection: -
Expert list: 1
Factory setting
0