DO: SERVO
Internal control/status words - Status word, current control
Status word closed-loop current control
Bit No.
0
1 = Closed-loop current control active
1
Reserved
2
Reserved
3
Reserved
4
1 = Limiting Ud active
5
1 = Limiting Uq active
6
1 = Pos. limit. Iq active
7
1 = Neg. limit. Iq active
8
1 = Iq setpoint limit. active
9
1 = Id setpoint limit. active
10
Reserved
11
Reserved
12
Reserved
13
Reserved
14
Reserved
15
Reserved
3
4
Meaning
5
6
Function diagram
fp_2530_98_eng.vsd
SINAMICS S110
30.10.08 V04.04.00
250 s
ZSW closed-loop
Refer to [1020.7]
current control
r1408
r1408.4
r1408.5
[5040.7][5042.5]
r1408.6
[5714.5]
r1408.7
[5714.4]
r1408.8
[5714.4]
r1408.9
[5722.7]