Parameter
List of parameters
p20283
LVM 1 run sequence / LVM 1 RunSeq
CU_S110-CAN,
Can be changed: T
CU_S110-DP,
Data type: Unsigned16
CU_S110-PN,
P-Group: -
SERVO_S110-CAN
Not for motor type: -
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Min
0
Description:
Setting parameter for the run sequence of instance LVM within the run-time group set in p20282.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20284
CI: DIF 0 input X / DIF 0 input X
CU_S110-CAN,
Can be changed: T
CU_S110-DP,
Data type: Unsigned32 / FloatingPoint32
CU_S110-PN,
P-Group: -
SERVO_S110-CAN
Not for motor type: -
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Min
-
Description:
Sets the signal source of input quantity X of instance DIF 0 of the differentiating element.
p20285
DIF 0 differentiating time constant in ms / DIF 0 T_diff ms
CU_S110-CAN,
Can be changed: T
CU_S110-DP,
Data type: FloatingPoint32
CU_S110-PN,
P-Group: -
SERVO_S110-CAN
Not for motor type: -
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Min
0.00
Description:
Sets the differentiating time constant Td in milliseconds of instance DIF 0 of the differentiating element.
r20286
CO: DIF 0 output Y / DIF 0 output Y
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: FloatingPoint32
CU_S110-PN,
P-Group: -
SERVO_S110-CAN
Not for motor type: -
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Min
-
Description:
Display parameter for output quantity Y of instance DIF 0 of the differentiating element.
1-730
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
7999
Calculated: -
Dynamic index: -
Units group: -
Scaling: PERCENT
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
340.28235E36
Calculated: -
Dynamic index: -
Units group: -
Scaling: PERCENT
Max
-
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 1
Func. diagram: 7270
Unit selection: -
Expert list: 1
Factory setting
730
Access level: 1
Func. diagram: 7264
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: 7264
Unit selection: -
Expert list: 1
Factory setting
0.00
Access level: 1
Func. diagram: 7264
Unit selection: -
Expert list: 1
Factory setting
-