r9872.0...24
CO/BO: SI status (processor 2) / SI Status P2
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Displays the Safety Integrated status on processor 2.
Bit field:
Bit
Signal name
00
STO on Motor Module selected
01
STO on Motor Module active
02
SS1 delay time on Motor Module active
03
Safe Brake Adapter feedback signal
04
SBC requested
05
SS1 selected on the Motor Module (Basic
Functions)
06
SS1 active on the Motor Module (Basic
Functions)
09
STOP A cannot be acknowledged, active
10
STOP A active
15
STOP F active
16
STO cse: Safety comm. mode
17
STO cause selection via terminal (Basic
Functions)
18
STO cause: selection via SMM
20
STO cause selection PROFIsafe (Basic
Functions)
22
SS1 cause selection terminal (Basic Func-
tions)
23
SS1 cause selection PROFIsafe (Basic
Functions)
24
Slave Motor Module ready for communica-
tion
Dependency:
Refer to: r9772
Notice:
If communication between processor 1 and processor 2 is interrupted, then this display parameter is no longer
updated. The last transferred status of processor 2 is displayed.
Note:
Re bit 00:
When STO is selected, the cause is displayed in bits 16 ... 18 and in bit 20.
Re bit 05:
When SS1 is selected, the cause is displayed in bits 22 and 23.
Re bit 18:
When the bit is set, STO is selected via PROFIsafe.
SMM: Safe Motion Monitoring
r9880
SI monitoring clock cycle (processor 2) / SI mon_clk cyc P2
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
- [ms]
Description:
Displays the clock cycle time for the Safety Integrated Basic Functions on processor 2.
Dependency:
Refer to: r9780
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
- [ms]
Parameter
List of parameters
Access level: 2
Func. diagram: 2804
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
FP
No
2810
No
2810
No
2810
No
2814
No
2814
No
-
No
-
No
2802
No
2802
No
2802
No
-
No
-
No
-
No
-
No
-
No
-
No
-
Access level: 3
Func. diagram: 2802
Unit selection: -
Expert list: 1
Factory setting
- [ms]