Siemens SINAMICS S110 List Manual page 636

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
p10124
SI SS2 input terminal (processor 2) / SI SS2 F-DI P2
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
0
Description:
Sets the fail-safe digital input (F-DI) for the "SS2" function.
Value:
0:
1:
2:
3:
255:
Note:
If value = 0:
No terminal assigned, safety function always active.
If value = 255:
No terminal assigned, safety function always inactive.
F-DI: Failsafe Digital Input
SS2: Safe Stop 2
p10125
SI SOS input terminal (processor 2) / SI SOS F-DI P2
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
0
Description:
Sets the fail-safe digital input (F-DI) for the "SOS" function.
Value:
0:
1:
2:
3:
255:
Note:
If value = 0:
No terminal assigned, safety function always active.
If value = 255:
No terminal assigned, safety function always inactive.
F-DI: Failsafe Digital Input
SOS: Safe Operating Stop
p10126
SI SLS input terminal (processor 2) / SI SLS F-DI P2
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
0
Description:
Sets the fail-safe digital input (F-DI) for the "SLS" function.
Value:
0:
1:
2:
3:
255:
Dependency:
Refer to: p10026
1-636
Statically active
F-DI 0
F-DI 1
F-DI 2
Statically inact
Statically active
F-DI 0
F-DI 1
F-DI 2
Statically inact
Statically active
F-DI 0
F-DI 1
F-DI 2
Statically inact
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
255
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
255
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
255
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0