Parameter
List of parameters
Bit field:
Bit
Signal name
00
Rdy for switch on
01
Ready
02
Operation enabled
03
Fault present
04
No coasting active
05
No Quick Stop active
06
Switching on inhibited active
07
Alarm present
08
Can be freely interconnected (BI: p8785)
09
Control request
10
Target reached
11
Torque limit reached
12
Velocity equal to zero
14
Can be freely interconnected (BI: p8786)
15
Can be freely interconnected (BI: p8787)
Note:
Corresponds to the CANopen object 6041 hex + 800 hex * x (x: Drive number 0 ... 7).
Re bit 10:
When the ramp-function generator is activated, the interconnection from CI: p2151 = r1119 can be changed, so that
to evaluate bit 10, the setpoint can be retrieved (taken) from in front of the ramp-function generator.
Re bit 10, 12:
When braking, the two bits must indicate the same state. This is the reason that the following parameters must be
set the same:
p2161 (speed threshold value 3, for r2199.0) = p2163 (speed threshold value 4, for r2197.7)
p2150 (hysteresis speed 3, for r2199.0) = p2164 (hysteresis speed 4, for r2197.7)
p8785
BI: CAN status word bit 8 / Status word bit 8
SERVO_S110-CAN
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: Communications
Not for motor type: -
Min
-
Description:
Binector input for CANopen status word bit 8.
Dependency:
Refer to: r8784
p8786
BI: CAN status word bit 14 / Status word bit 14
SERVO_S110-CAN
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: Communications
Not for motor type: -
Min
-
Description:
Binector input for CANopen status word bit 14.
Dependency:
Refer to: r8784
p8787
BI: CAN status word bit 15 / Status word bit 15
SERVO_S110-CAN
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: Communications
Not for motor type: -
Min
-
Description:
Binector input for CANopen status word bit 15.
Dependency:
Refer to: r8784
1-522
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
High
Yes
Yes
Yes
Yes
High
High
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
0 signal
FP
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
Low
-
No
-
No
-
No
-
No
-
Low
-
Low
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0