Siemens SINAMICS S110 List Manual page 541

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

p9352
SI Motion transition time STOP C to SOS (processor 2) / SI Mtn t C->SOS P2
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [µs]
Description:
Sets the transition time from STOP C to "Safe Operating Stop" (SOS).
Dependency:
Refer to: p9552
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
SOS: Safe Operating Stop
p9353
SI Motion transition time STOP D to SOS (processor 2) / SI Mtn t D->SOS P2
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [µs]
Description:
Sets the transition time from STOP D to "Safe Operating Stop" (SOS).
Dependency:
Refer to: p9553
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
SOS: Safe Operating Stop
p9354
SI Motion transition time STOP E to SOS (processor 2) / SI Mtn t E->SOS P2
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [µs]
Description:
Sets the transition time from STOP E to "Safe Operating Stop" (SOS).
Dependency:
Refer to: p9554
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
SOS: Safe Operating Stop
p9355
SI Motion transition time STOP F to STOP B (processor 2) / SI Mtn t F->B P2
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [µs]
Description:
Sets the transition time from STOP F to STOP B.
Dependency:
Refer to: C01711
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
600000000.00 [µs]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
600000000.00 [µs]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
600000000.00 [µs]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
600000000.00 [µs]
Parameter
List of parameters
Access level: 3
Func. diagram: 2825
Unit selection: -
Expert list: 1
Factory setting
100000.00 [µs]
Access level: 3
Func. diagram: 2825
Unit selection: -
Expert list: 1
Factory setting
100000.00 [µs]
Access level: 3
Func. diagram: 2825
Unit selection: -
Expert list: 1
Factory setting
100000.00 [µs]
Access level: 3
Func. diagram: 2825
Unit selection: -
Expert list: 1
Factory setting
0.00 [µs]
1-541

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents