Parameter
List of parameters
p8701[0...1]
CAN Receive PDO 2 / Receive PDO 2
SERVO_S110-CAN
Can be changed: C1(3), T
Data type: Unsigned32
P-Group: Communications
Not for motor type: -
Min
0000 hex
Description:
Sets the communication parameters for CANopen Receive Process Data Object 2 (RPDO 2).
Index:
[0] = PDO COB-ID
[1] = PDO transmission type
Dependency:
A valid COB-ID can only be set for the available (existing) channel.
Refer to: p8741
Note:
Corresponds to the CANopen object 1401 hex + 40 hex * x (x: Drive number 0 ... 7).
Transmission types 0, 1, FE and FF can be set.
PDO: Process Data Object
p8702[0...1]
CAN Receive PDO 3 / Receive PDO 3
SERVO_S110-CAN
Can be changed: C1(3), T
Data type: Unsigned32
P-Group: Communications
Not for motor type: -
Min
0000 hex
Description:
Sets the communication parameters for CANopen Receive Process Data Object 3 (RPDO 3).
Index:
[0] = PDO COB-ID
[1] = PDO transmission type
Dependency:
A valid COB-ID can only be set for the available (existing) channel.
Refer to: p8741
Note:
Corresponds to the CANopen object 1402 hex + 40 hex * x (x: Drive number 0 ... 7).
Transmission types 0, 1, FE and FF can be set.
PDO: Process Data Object
p8703[0...1]
CAN Receive PDO 4 / Receive PDO 4
SERVO_S110-CAN
Can be changed: C1(3), T
Data type: Unsigned32
P-Group: Communications
Not for motor type: -
Min
0000 hex
Description:
Sets the communication parameters for CANopen Receive Process Data Object 4 (RPDO 4).
Index:
[0] = PDO COB-ID
[1] = PDO transmission type
Dependency:
A valid COB-ID can only be set for the available (existing) channel.
Refer to: p8741
Note:
Corresponds to the CANopen object 1403 hex + 40 hex * x (x: Drive number 0 ... 7).
Transmission types 0, 1, FE and FF can be set.
PDO: Process Data Object
1-508
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
8000 06DF hex
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
8000 06DF hex
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
8000 06DF hex
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: 9204, 9206
Unit selection: -
Expert list: 1
Factory setting
[0] 8000 06DF hex
[1] 00FE hex
Access level: 3
Func. diagram: 9204, 9206
Unit selection: -
Expert list: 1
Factory setting
[0] 8000 06DF hex
[1] 00FE hex
Access level: 3
Func. diagram: 9204, 9206
Unit selection: -
Expert list: 1
Factory setting
[0] 8000 06DF hex
[1] 00FE hex