3. WIRE FAILURE
NO RESTART:
ALARM AT ARC END :
SEMI-AUTO RESTART :

Automatic Wire Anti-stick Function Setting

NO. (0 to 9 times)
Maximum repetition count for the wire-sticking release process.
CURRENT (1 to 999A)
The welding current output in the wire-sticking release process.
VOLTAGE (0 to 50.0V, 50 to 150%)
The welding voltage output in the wire-sticking release process.
CLOCK (0 to 2.00 seconds)
Sticking release process duration.
Arc restart function is not used. The manipulator moves
with the wire shortage alarm.
The manipulator continues the welding operation until it
reaches the welding end point, where it stops with an
alarm.
The manipulator stops and waits for manual intervention.
The manipulator restarts as the operator presses [START]
again. The restart status is reset when OUT #1022 is
turned ON and OFF.
DATA
EDIT
DISPLAY
ARC AUXILIARY COND
COND NO.; 1
<WIRE ANTI-STICKING FUNCTION SET>
NO.
CURRENT
VOLTAGE
CLOCK
Main Menu
ShortCut
9-50
9 Arc Welding Application
9.5 Welding Condition Files
UTILITY
:
1
times
: 110 A
: 120 %
: 0.30 sec
! Turn on servo power