Function
Additional
DIN
Item
Example
Function
WAIT
Additional
Item
Example
Function
AOUT
Additional
Item
Example
Sets input signals in variables.
B<variable number>
IN# (<input number>),
IGH# (<input group number>),
IG# (<input group number>),
OT# (<output number>),
OGH# (<output group number>),
OG# (<output group number>),
SIN# (<system input number>),
SOUT# (<system output number>)
Number of addressed input signals:
IN#(xx)=1;IGH#(xx)=4(per group);
IG#(xx)=8(per group)
Number of addressed output signals:
OT#(xx)=1;OGH#(xx)=4(per group);
OG#(xx)=8(per group)
IGH#(xx) and OGH#(xx) are not subject to parity
check; only the binary specification is allowed.
DIN B016 IN#(16)
DIN B002 IG#(2)
Waits until the external input signal status matches the specified
status.
IN# (<input number>),
IGH# (<input group number>),
IG# (<input group number>),
OT# (<user output number>),
OGH# (<output group number>),
SIN# (<system input number>),
SOUT# (<system output number>)
<status>,B<variable number>
T=<time (seconds)>
WAIT IN# (12)=ON T=10.00
WAIT IN# (12)=B002
Outputs the specified voltage to the general-purpose analog output
port.
AO# (<output port number>)
<output voltage(V)>
AOUT AO# (2) 12.7