9 Arc Welding Application
9.12 Power Source Condition File
WIRE ANTI-STICKING (0 to 9.9 seconds)
Specifies the duration of the wire anti-stick process at the end of welding.
ARC FAILURE STOP (0 to 2.55 seconds)
Specifies the time between the detection of arc failure and the stopping of the manipulator
movement.
POWER SOURCE CONDITION Window for Current/Voltage Output
RANGE
Indicates the polarity of the reference value for the welding current and voltage. If the range
is positive (+), the reference value is in the range between 0 and 14.00V. If the range is
negative (-), the reference value is in the range between 0 and -14.00V.
ADJUST (0.80 to 1.20)
A correction value to adjust the welding current/voltage output.
REF. (V) (0 to 14.00V)
Welding current/voltage reference values.
MEASURE (0 to 999A, 0 to 50.0V, or 50 to 150%)
The welding current/voltage output values measured at the reference values as given under
.
DATA
EDIT
DISPLAY
POWER SOURCE CONDITION
POWER SOURCE NO.: 1/1
<CURRENT OUTPUT CHAR.> <WELDING VOLTAGE OUTPUT CHAR.>
RANGE:
+
ADJUST: 1.00
NO.
REF.(V) MEASURE (A) REF.(V) MEASURE (%)
01
0.00
30
02
1.35
62
03
2.70
94
04
10.80
286
05
12.15
318
06
13.50
350
07
0.00
0
08
0.00
0
Main Menu
ShortCut
9-89
UTILITY
+
1.00
0.00
50
7.20
99
7.50
100
7.80
101
14.00
150
0.00
0
0.00
0
0.00
0