9 Arc Welding Application
9.12 Power Source Condition File
WIRE ANTI-STICKING (0 to 9.9 seconds)
Specifies the duration of the wire anti-stick process at the end of welding.
ARC FAILURE STOP (0 to 2.55 seconds)
Specifies the time between the detection of arc failure and the stopping of the manipulator
movement.
POWER SOURCE CONDITION Window for Current/Voltage Output
RANGE
Indicates the polarity of the reference value for the welding current and voltage. If the range
is positive (+), the reference value is in the range between 0 and 14.00V. If the range is
negative (-), the reference value is in the range between 0 and -14.00V.
ADJUST (0.80 to 1.20)
A correction value to adjust the welding current/voltage output.
REF. (V) (0 to 14.00V)
Welding current/voltage reference values.
MEASURE (0 to 999A, 0 to 50.0V, or 50 to 150%)
The welding current/voltage output values measured at the reference values as given under
.
DATA
EDIT
DISPLAY
POWER SOURCE CONDITION
POWER SOURCE NO.: 1/1
<CURRENT OUTPUT CHAR.> <WELDING VOLTAGE OUTPUT CHAR.>
RANGE:
+
ADJUST: 1.00
NO.
REF.(V) MEASURE (A) REF.(V) MEASURE (%)
01
0.00
30
02
1.35
62
03
2.70
94
04
10.80
286
05
12.15
318
06
13.50
350
07
0.00
0
08
0.00
0
Main Menu
ShortCut
9-89
UTILITY
+
1.00
0.00
50
7.20
99
7.50
100
7.80
101
14.00
150
0.00
0
0.00
0
0.00
0
!Turn on servo power