149235-1CD
8.9
TRANSMISSION PARAMETERS
RS000: COMMUNICATION PROTOCOL
The protocol of the serial port of the NCP01 circuit board is specified.
0:
No protocol
2:
Basic protocol
3:
FC1 protocol
8.9.1
Basic Protocol
Specify when using Yaskawa data transmission functions.
RS030: NUMBER OF DATA BITS
This parameter specifies the number of data bits.
RS031: NUMBER OF STOP BITS
This parameter specifies the number of stop bits.
RS032: PARITY
This parameter specifies the parity bits.

RS033: TRANSMISSION SPEED

This parameter specifies the transmission speed in units of bauds.
RS034: RESPONSE WAITING TIMER (TIMER A)
Units: 0.1 seconds
This timer monitors the sequence. It specifies the response waiting time for invalid or missing
responses.
RS035: TEXT TERMINATION MONITORING TIMER (TIMER B)
This timer monitors text reception. Specify the monitoring time to wait for text termination character.
RS036: NUMBER OF ENQ RE-TRANSMISSION RETRIES
This parameter specifies the number of re-transmission attempts of the control characters for invalid or
missing responses.
RS037: NUMBER OF DATA RE-TRANSMISSION RETRIES
This parameter specifies the number of re-transmission attempts of text for block check error (NAK
reception).
RS038: BLOCK CHECK METHOD
This parameter specifies the checking method for text transmission errors. Set "0" for this protocol.
8.9 TRANSMISSION PARAMETERS
8-50
8 Parameter
339 of 493
RE-CSO-A031

Hide quick links: