YASKAWA NX100 Operator's Manual page 368

Hide thumbs Also See for NX100:
Table of Contents

Advertisement

9 Arc Welding Application
9.4 Registering Arc Welding Instructions
With an Arc End Condition File
Operation
1
Select the ARCOF instruction
in the instruction area.
2
Press [SELECT].
3
Select "UNUSED."
The ARCOF instruction appears in the input buffer line.
JOB
EDIT
JOB CONTENT
JOB NAME: WORK A
CONTROL GROUP: R1
0000
NOP
0001
MOVJ VJ=80.00
0002
MOVL V=800
0003
ARCON
0004
MOVL V=50
0005
MOVL V=50
0006
MOVL V=50
0007
END
ARCOF
Main Menu
ShortCut
The DETAIL EDIT window appears.
DATA
EDIT
DETAIL EDIT
ARCOF
SET METHOD
ARCOF
Main Menu
ShortCut
The selection dialog box appears.
DATA
EDIT
DETAIL EDIT
ARCOF
SET METHOD
9-25
Explanation
DISPLAY
UTILITY
STEP NO: 0003
TOOL: 00
! Turn on servo power
DISPLAY
UTILITY
:
UNUSED
! Turn on servo power
DISPLAY
UTILITY
:
AEF#()
AC=
UNUSED
149235-1CD
368 of 493
RE-CSO-A031

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents