• Play Speed V:
NOTE
MOVL V=I000
The variable I000 is used for speed V with this move instruction.
The unit for V is 0.1mm per second.
For example, if I000 were set as 1000, the following would be true:
I000=1000  unit for V is 0.1mm/s  V=100.0 mm/s
Note that, depending on the unit being used, the value of the variable and the value of the
actual speed on occasion might not match.
• Play Speed VJ:
MOVL VJ=I000
The unit for VJ is 0.01%.
For example, if I000 were set as 1000, the following would be true:
I000=1000  unit for VJ is 0.01%  VJ=10.00%.
• Timer T:
TIMER T=I000
The unit for T is 0.01 seconds.
For example, if I000 were set as 1000, the following would be true:
I000=1000  unit for T is 0.01 seconds  T=10.00 seconds.