149235-1CD
9.5.5
Arc Auxiliary Condition File
An arc auxiliary condition file has the following three parts:
• Arc Retry Function Setting
• Arc Restart Function Setting
• Automatic Wire Anti-stick Function Setting
Arc Retry Function Setting
NO. (0 to 9 times)
Maximum repetition count for the arc retry process.
RETRACT TIME (0 to 2.50 seconds)
Wire retracting time in the arc retry process.
REPLAY DISTANCE (0 to 99.9 mm)
Manipulator moving distance for an arc retry process at the replay mode.
SPEED (1 to 600 cm/min)
Speed of the manipulator when it returns to the welding start point at arc retry.
CURRENT (1 to 999A)
Welding current output when the manipulator returns to the welding start point at arc retry.
VOLTAGE (0 to 50.0V, 50 to 150%)
Welding voltage output when the manipulator returns to the welding start point at arc retry.
DATA
EDIT
DISPLAY
ARC AUXILIARY COND
COND NO.: 1
<RETRY FUNCTION SET>
NO.
RETRACT TIME
REPLAY DISTANCE
SPEED
CURRENT
VOLTAGE
Main Menu
ShortCut
9-48
9 Arc Welding Application
9.5 Welding Condition Files
UTILITY
:
1
times
: 1.50 sec
: 10.0 mm
:
30 cm/min
: 100 A
: 100 %
! Turn on servo power