Arcon Instruction - YASKAWA NX100 Operator's Manual

Hide thumbs Also See for NX100:
Table of Contents

Advertisement

149235-1CD
The maximum current and voltage values are determined according to the voltage and
NOTE
current characteristics of the Power Source.
< Example >
When using a Power Source with the current characteristics as shown in the following
table:
When the data points are interpolated on the graph, it can be observed that the maximum
reference value (14.0V) is reached when the welding current specified by the ARCON
instruction is 395 A. This becomes the maximum value.
Measured value
(A)
400
300
200
100
0
2
Welding Current Output Characteristics

ARCON Instruction

The ARCON instruction without an additional item is not subject to arc condition rewriting.
ARCON ASF#(1)
ARCON AC=220 AVP=100: Current and voltage values can be rewritten.
ARCON
ARCOF Instruction
The conditions of the ARCOF instruction cannot be rewritten.
4
6
8
10
12
14
Max
: Current and voltage values can be rewritten.
: Conditions cannot be rewritten.
9-62
9.6 Changing Welding Conditions During Playback
Command
Value
(V)
1.80
4.40
6.40
8.30
10.50
0
0
0
(V)
16
Reference
value
9 Arc Welding Application
Measurement
Value
(A)
110
165
220
265
315
0
0
0
405 of 493
RE-CSO-A031

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents