9 Arc Welding Application

9.12 Power Source Condition File

9.12 Power Source Condition File
9.12.1
About Power Source Condition File
This is the file where the Power Source characteristics: voltage characteristic, etc., is registered. This
file contains the information for Power Source control.
For precise control of the welding current and voltage, the control signals sent from the controller to the
Power Source must be properly adjusted.
The voltage of the current control signal is called the welding current reference value; the voltage of the
voltage control signal is called the welding voltage reference value. A reference value is in the range
between 0 and 14V (or between 0 and -14 depending on Power Sources).
How the output of the welding current or voltage changes with the reference value depends on the
Power Source model, and this relationship between the reference value and output value is called an
output characteristics. Each Power Source condition data file contains the output values (measured
values) associated with several reference values. The figure below is an example of the welding
current output characteristic curve.
Welding current
output value
( A )
230
200
170
140
100
0
The inclination between the last
two points is extended beyond
the last point
1
2.2
3
4
Welding current reference value
Welding Current Output Characteristics (Example)
9-85
Correction value = 1.2
Welding current output characteristics
Correction value = 0.8
: Data point
5
( V )