149235-1CD
S2C336: JOB LINKING DESIGNATION (When Twin Synchronous
Function Used)
This parameter specifies whether the manipulator at the synchronizing side is to be linked when the
manipulator and the station at the synchronized side are performing FWD/BWD or test run, by using the
twin synchronous function.
0:
Not operating
1:
Linking
0 : Does not operate the synchronizing side
while teaching the synchronized side.
1 : Links the synchronizing side while teaching
the synchronized side.
Synchronizing side