Setting Welding Start Conditions

The ARCON instruction can be registered in any of the following three ways:
• With additional items to specify conditions
ARCON AC=200 AVP=100 T=0.50 V=60 RETRY
• With an arc start condition file
ARCON ASF# (1)
In this case, the welding condition is set using the arc start condition file. (Refer to section
9.5 "Welding Condition Files")
• Without additional items
ARCON
In this case, the welding condition must be set using the welding condition set instruction
(ARCSET) before the ARCON instruction is executed. (Refer to section 9.4.3
"ARCSET".")
With Additional Items to Specify Conditions
Operation
1
Select the ARCON instruction
in the instruction area.
2
Press [SELECT].
The ARCON instruction appears in the input buffer line.
JOB
EDIT
JOB CONTENT
JOB NAME: WORK A
CONTROL GROUP: R1
0000
NOP
0001
MOVJ VJ=80.00
0002
MOVL V=800
0003
END
ARCON
Main Menu
ShortCut
The DETAIL EDIT window appears. Select "UNUSED."
DATA
EDIT
DETAIL EDIT
ARCON
SET METHOD
ARCON
Main Menu
ShortCut
9-14
9 Arc Welding Application
9.4 Registering Arc Welding Instructions
Explanation
DISPLAY
UTILITY
STEP NO: 0003
TOOL: 00
! Turn on servo power
UTILITY
DISPLAY
:
UNUSED
! Turn on servo power