149235-1CD
9.4.3

ARCSET

This is the instruction to set the welding conditions (current, voltage, etc.) individually.
The ARCSET instruction can be registered in any of the following two ways:
• With additional items to specify conditions
ARCSET AC=200 AVP=100
• With an arc start condition file
ARCSET ASF# (1)
In this case, the welding condition is set using the arc start condition file.
(Refer to section 9.5 "Welding Condition Files")
Registering the ARCSET Instruction
With Additional Items to Specify Conditions
Operation
1
Move the cursor to the
address area.
2
Press [INFORM LIST].
3
Select "DEVICE."
4
Select the ARCSET
instruction.
The instruction list dialog box appears.
ARCON
ARCOF
VWELD
AWELD
ARCSET
WVON
WVOF
ARCCTS
The ARCSET instruction appears in the input buffer line.
EDIT
JOB
JOB CONTENT1
JOB NAME: WORK A
CONTROL GROUP: R1
0000
NOP
0001
MOVJ VJ=80.00
0002
MOVL V=800
0003
ARCON
0004
MOVL V=50
0005
END
ARCSET AC=200 AVP=100
Main Menu
ShortCut
9-30
9 Arc Welding Application
9.4 Registering Arc Welding Instructions
Explanation
IN/OUT
ARCCTE
CONTROL
DEVICE
MOTION
ARITH
SHIFT
OTHER
SAME
PRIOR
DISPLAY
UTILITY
STEP NO: 0003
ARCON
ARCCTE
TOOL: 00
ARCOF
VWELD
AWELD
ARCSET
WVON
WVOF
ARCCTS
! Turn on servo power
IN/OUT
CONTROL
DEVICE
MOTION
ARITH
SHIFT
OTHER
SAME
PRIOR
373 of 493