Arc End Condition File - YASKAWA NX100 Operator's Manual

Hide thumbs Also See for NX100:
Table of Contents

Advertisement

9 Arc Welding Application
9.5 Welding Condition Files
9.5.4

Arc End Condition File

COND NO. (1 to 396)
Displays a condition number between 1 and 396.
COMM.
Displays a comment of 32 characters or less.
CURRENT (1 to 999A)
Welding current output value at the end of welding.
VOLTAGE (0 to 50.0V, 50 to 150%)
Welding voltage output value at the end of welding.
ROBOT PAUSE TIME (0 to 10.00 seconds)
The period during arc end when the manipulator is stopped.
ANTI-STICK
Specifies whether the automatic wire anti-stick function is used or not.
MONITORING(0 to 9.9 seconds)
Wire stick monitoring time at the end of welding.
WELDER CONTROL PRMTR (0000 to 9999, 10000: NOT USED)
At the beginning of welding, the value (0 to 9999) specified in the "WELDER CONTROL
PRMTR" is output to the following system register. At the end of welding, the same welder
control parameter can be specified, overwriting the same system register.
System register for each application "WELDER CONTROL PRMTR"
M468: device 1 (--> register for arc 1)
M478: device 2 (--> register for arc 2)
M488: device 3 (--> register for arc 3)
M498: device 4 (--> register for arc 4)
*Set the value to 10000 when "WELDER CONTROL PRMTR" is not used.
DATA
EDIT
DISPLAY
ARC END CONDITION
COND NO.: 1/396
COMM.
weld1
CURRENT
VOLTAGE
ROBOT PAUSE TIME
ANTI-STICK
MONITORING
WELDER CONTROL PRMTR
UTILITY
: 120 A
:
80 %
: 0.01 sec
: OFF
: 0.2 sec
: NOT USED
9-47