I/O Instructions - YASKAWA NX100 Operator's Manual

Hide thumbs Also See for NX100:
Table of Contents

Advertisement

10 Table of Basic Instructions

10.2 I/O Instructions

10.2 I/O Instructions
Function
DOUT
Additional
Example
Function
PULSE
Additional
Example
Turns the external output signals ON and OFF.
OT# (<output number>),
OGH# (<output group number>),
OG# (<output group number>)
Number of addressed output signals:
OT#(xx)=1;OGH#(xx)=4(per group);
OG#(xx)=8(per group)
Item
OGH#(xx) is not subject to parity check; only the
binary specification is allowed.
FINE
DOUT OT#(12) ON
Outputs a pulse signal as an external output signal.
OT# (<output number>),
OGH# (<output group number>),
OG# (<output group number>)
T=<time (seconds)>
Item
PULSE OT# (10) T=0.60
10-5
149235-1CD
With a high
degree of
accuracy
0.01 to
655.35 s
0.30 s unless
otherwise
specified
460 of 493