AxP011, AxP012: MANUAL WIRE OPERATION SPEED

These parameters specify the manual wire operation speed as a percentage of the maximum
instruction value. Instruction polarity is determined by the current instruction in the Power Source
characteristic file. The setting range is from 0 to 100.
AxP013, AxP014: WELDING CONTROL TIME
These parameters specify the welding control time in units of minutes. The setting range is from 0 to
999.
AxP015 to AxP017: NUMBER OF WELDING CONTROL
These parameters specify the number of welding controls. The setting range is from 0 to 99.
AxP026 to AxP029: TOOL ON/OFF USER OUTPUT NO. (Jigless
system)
These parameters specify the user output number for the tool open/close operation by specific keys.
8.10.2
Handling Application
AxP002, AxP004: f1 KEY FUNCTION
These parameters set the output signal to assign for f1 key.
0: Not specified
1 to 4: Specific outputs for HAND-1 to HAND4-1
5: User output (No. is specified by AxP004).
AxP003, AxP005: f2 KEY FUNCTION
These parameters set the output signal to assign for f2 key.
0: Not specified
1 to 4: Specific outputs for HAND-2 to HAND4-2
5: User output (No. is specified by AxP005)
8.10.3
Spot Welding
AxP003: MAXIMUM NUMBERS OF CONNECTED POWER
SOURCES
The initial value is set to 4. The value is automatically set at start-up. No modification is needed.
AxP004: GUN FULL OPEN STROKE ON/OFF SIGNAL
This parameter specifies which stroke switching signal is output ON or OFF to make the gun fully-
opened for each gun.
Bit specification (1 for 01) for 8 guns. The initial setting is "0."
0 0 0 0 0 0 0 0
| | | | | | | |
8 7 6 5 4 3 2 1
Gun number