Changing Welding Conditions - YASKAWA NX100 Operator's Manual

Hide thumbs Also See for NX100:
Table of Contents

Advertisement

149235-1CD
9.6.2

Changing Welding Conditions

Operation
1
Select {UTILITY} on the JOB
CONTENT window in the play
mode.
2
Select {WELD COND.
ADJUST.}.
3
Line up the cursor with the
current or voltage condition to
be modified.
4
Adjust the value using [CUR/
VOL ] or [CUR/VOL].
9.6 Changing Welding Conditions During Playback
The ARC COND ADJUSTMENT window appears.
The last instruction that sets the welding current or voltage is
displayed.
The instruction includes the following:
• ARCON
• ARCSET
DATA
EDIT
ARC COND ADJUSTMENT
CURR(A)
:
200
VOLT(%)
: 100 INST : ARCON
DATA
: No change data
Main Menu
ShortCut
• The current and voltage can be independently changed.
• Units of Increase/Decrease: If the key is pressed once, the
current value increases/decreases in units of ± 1A, and the
voltage value increases/decreases in units of ± 0.1V or in
percentages of ± 1%.
DATA
EDIT
ARC COND ADJUSTMENT
CURR(A)
:
200
VOLT(%)
: 100 INST : ARCON
DATA
EDIT
ARC COND ADJUSTMENT
CURR(A)
:
200
VOLT(%)
:
100
9-60
9 Arc Welding Application
Explanation
DISPLAY
UTILITY
INST : ARCON
! Turn on servo power
UTILITY
DISPLAY
INST : ARCON
DISPLAY
UTILITY
INST : ARCON
INST : ARCON
403 of 493