149235-1CD
11.1.5

Concurrent I/O

Error No.
Data
*
Illegal relay No.
4010
XXX
*
Illegal instruction
4030
XXX
Relay/register No. duplicated in OUT/
*
GOUT or arithmetic instruction
4040
XXX
*
The relay is not used
4050
XXX
*
Excess STR-[-NOT] instructions
4060
XXX
*
Excess AND [OR] STR instructions
4070
XXX
*
Syntax error in CNT instructions
4080
XXX
*
Enter STR [-NOT] at head of block
4090
XXX
Concurrent I/O memory is full
4120
-
4130
-
END instruction not found
Wrong ladder program
4140
-
Wrong use of GSTR, GOUT commands
*
4150
XXX
Excess TMR/CNT or arithmetic
4220
-
instructions
4230
-
Syntax error in TMR/CNT instructions
Error Message
11-15
11.1 Error Message List
Contents
Line No.
Line No.
Multiple outputs are instructed to
the relay or register.
Line No.
Line No.
Line No.
Line No.
Line No.
Need STR [-NOT]
Line No.
Exceeds memory capacity
(10000 steps)
END instruction not found
Position and number of PART
instruction are wrong.
GSTR and GOUT is not used
together.
Line No.
More than 100 TMR, CNT or
arithmetic instruction used
RE-CSO-A031