System Input Signal - YASKAWA NX100 Operator's Manual

Hide thumbs Also See for NX100:
Table of Contents

Advertisement

9 Arc Welding Application
9.11 Weaving Condition File
Method to Prohibit Weaving by Means of a System Input Signal
The system input signal 40047 is used.
The system input signal can prohibit weaving at any time during a play operation, regardless of whether
or not it is a check operation.
9.11.5
Registering Weaving Instructions
WVON Instruction
This is the weaving start operation.
Operation
1
Move the cursor to the
address area.
2
Press [INFORM LIST].
3
Select "DEVICE."
4
Select the WVON instruction.
The instruction list dialog box appears.
The "WVON" instruction appears in the input buffer line.
JOB
EDIT
JOB CONTENT
JOB NAME: WORK A
CONTROL GROUP: R1
0000 NOP
0001 MOVJ VJ=80.00
0002 MOVL V=800
0003 ARCON
0004 MOVL V=50
0005 MOVL V=50
0006 ARCOF
0007 END
WVON WEV#(1)