9 Arc Welding Application
9.13 Power Source Condition File Initial Value
POWER SOURCE NO.: 13
POWER SOURCE NAME:
MOTOWELD-S350-AJ2/3
COMMENT: STC CONTROL
POWER SUPPLY: A (synergic)
SHIELDING GAS: CO2
WIRE DIA.: 1.2mm
WIRE STICKOUT: 15mm
WIRE ANTI-STICKING: 0.3sec
ARC FAILURE STOP: 0.6sec
CURRENT
RANGE: positive
ADJ.: 1.00
REF.
MEA.
(V)
(A)
1.00
100
2.00
140
3.50
190
5.00
230
7.00
270
10.00
350
0.00
0
0.00
0
VOLTAGE
RANGE: positive
ADJ.: 1.00
REF.
MEA.
(V)
(%)
3.00
85
5.00
95
7.00
100
9.00
105
10.00
110
0.00
0
0.00
0
0.00
0
9-103
POWER SOURCE NO.: 14
POWER SOURCE NAME:
MOTOWELD-S350-AJ2/3
COMMENT: STC CONTROL
POWER SUPPLY: A (synergic)
SHIELDING GAS: MAG
WIRE DIA.: 1.2mm
WIRE STICKOUT: 15mm
WIRE ANTI-STICKING: 0.3sec
ARC FAILURE STOP: 0.6sec
CURRENT
RANGE: positive
RANGE: positive
ADJ.: 1.00
ADJ.: 1.00
REF.
MEA.
(V)
(A)
1.00
95
2.00
150
3.50
190
5.00
240
7.00
270
9.00
350
0.00
0
0.00
0
149235-1CD
VOLTAGE
REF.
MEA.
(V)
(%)
3.00
85
5.00
95
7.00
100
9.00
105
10.00
110
0.00
0
0.00
0
0.00
0