8 Parameter
8.3 Mode Operation Setting Parameters

S2C174: RESERVED START

This parameter specifies whether a reserved start instruction from the programming pendant is
accepted or not. The specification can be done on the OPERATING CONDITION window.
0:
Permitted
1:
Prohibited
S2C176: JOB SELECTION AT REMOTE FUNCTION (PLAY
MODE)
This parameter specifies whether a job selection in play mode at remote function is prohibited or not.
0:
Permitted
1:
Prohibited
S2C177: EXTERNAL MODE SWITCH
This parameter specifies whether mode switching from the outside is accepted or not. The
specification can be done on the OPERATING CONDITION window.
0:
Permitted
1:
Prohibited
S2C179: EXTERNAL CYCLE SWITCHING
This parameter specifies whether cycle switching from the outside is accepted or not. The specification
can be done on the OPERATING CONDITION window.
0:
Permitted
1:
Prohibited
S2C180: PROGRAMMING PENDANT CYCLE SWITCHING
This parameter specifies whether cycle switching from the programming pendant is accepted or not.
The specification can be done on the OPERATING CONDITION window.
0:
Permitted
1:
Prohibited
S2C181: SERVO ON FROM EXTERNAL PP PROHIBITION
This parameter specifies whether a servo ON instruction is accepted or not. More than one instruction
can be specified. For example, to permit the servo ON instruction from an external input only, set "6."
In this case, servo ON instruction from the programming pendant is not accepted.The specification can
be done on the OPERATING CONDITION window.
d 7
d 0
E xte rn a l in p u t p r o h ib ite d
P ro g ra m m in g p e n d a n t
D S W
8-17
149235-1CD
: 1 (V A L ID )
: 2 (V A L ID )
: 4 (V A L ID )