9 Arc Welding Application
9.6 Changing Welding Conditions During Playback
Operation
5
Line up the cursor with "No
change data" and press
[SELECT].
9.6.3

Notes on Modification of Welding Conditions

When Condition Data cannot be Modified
In the following cases, the window returns to the previous window of the ARC COND ADJUSTMENT
window. Even if the function keys are pressed, current and voltage cannot be modified.
• The mode is switched (to the teach mode, for example).
• An emergency stop is ON.
Each time [SELECT] is pressed, the setting alternates between
"No change data" and "Change data."
• To rewrite the modified condition file or additional item data, set
"Change data."
The data are rewritten when the execution of the instruction
which includes the changed condition data ends.
• If "No change data" is set before execution ends, the data is not
rewritten.
DATA
EDIT
ARC COND ADJUSTMENT
CURR(A)
:
200 INST : ARCON
VOLT(%)
: 100 INST :
DATA
:
No change data
EDIT
DATA
ARC COND ADJUSTMENT
CURR(A)
:
200 INST : ARCON
VOLT(%)
: 100 INST :
DATA
:
Change data
Even if control jumps from one job to another job,
NOTE
rewriting of the arc condition for the former job is
performed.