2.3 Parameters for data sets
p1015[0...n]
p1030[0...n]
p1037[0...n]
p1038[0...n]
p1040[0...n]
p1047[0...n]
p1048[0...n]
p1058[0...n]
p1059[0...n]
p1063[0...n]
p1080[0...n]
p1082[0...n]
p1083[0...n]
p1086[0...n]
p1091[0...n]
p1092[0...n]
p1093[0...n]
p1094[0...n]
p1101[0...n]
p1120[0...n]
p1121[0...n]
p1130[0...n]
p1131[0...n]
p1134[0...n]
p1135[0...n]
p1136[0...n]
p1137[0...n]
p1145[0...n]
p1148[0...n]
p1151[0...n]
p1189[0...n]
p1200[0...n]
p1202[0...n]
p1203[0...n]
p1226[0...n]
p1240[0...n]
p1243[0...n]
p1245[0...n]
p1247[0...n]
p1249[0...n]
p1250[0...n]
p1251[0...n]
p1252[0...n]
p1255[0...n]
p1256[0...n]
p1257[0...n]
p1262[0...n]
p1270[0...n]
p1271[0...n]
p1280[0...n]
p1281[0...n]
p1283[0...n]
p1284[0...n]
p1285[0...n]
p1287[0...n]
1072
CO: Fixed speed setpoint 15 / n_set_fixed 15
Motorized potentiometer configuration / Mop configuration
Motorized potentiometer maximum speed / MotP n_max
Motorized potentiometer minimum speed / MotP n_min
Motorized potentiometer starting value / Mop start value
Motorized potentiometer ramp-up time / Mop ramp-up time
Motorized potentiometer ramp-down time / Mop ramp-down time
Jog 1 speed setpoint / Jog 1 n_set
Jog 2 speed setpoint / Jog 2 n_set
Setpoint channel speed limit / Setp_chan n_lim
Minimum speed / n_min
Maximum speed / n_max
CO: Speed limit in positive direction of rotation / n_limit pos
CO: Speed limit in negative direction of rotation / n_limit neg
Skip speed 1 / n_skip 1
Skip speed 2 / n_skip 2
Skip speed 3 / n_skip 3
Skip speed 4 / n_skip 4
Skip speed bandwidth / n_skip bandwidth
Ramp-function generator ramp-up time / RFG ramp-up time
Ramp-function generator ramp-down time / RFG ramp-down time
Ramp-function generator initial rounding-off time / RFG t_start_round
Ramp-function generator final rounding-off time / RFG t_end_delay
Ramp-function generator rounding-off type / RFG round-off type
OFF3 ramp-down time / OFF3 t_RD
OFF3 initial rounding-off time / RFGOFF3 t_strt_rnd
OFF3 final rounding-off time / RFG OFF3 t_end_del
Ramp-function generator tracking intensity. / RFG track intens
Ramp-function gen. tolerance for ramp-up and ramp-down active / RFG tol HL/RL act
Ramp-function generator configuration / RFG config
Speed setpoint configuration / n_ctrl config
Flying restart operating mode / FlyRest op_mode
Flying restart search current / FlyRest I_srch
Flying restart search rate factor / FlyRst v_Srch Fact
Threshold for zero speed detection / n_standst n_thresh
Vdc controller or Vdc monitoring configuration / Vdc ctrl config
Vdc_max controller dynamic factor / Vdc_max dyn_factor
Vdc_min controller switch-in level (kinetic buffering) / Vdc_min on_level
Vdc_min controller dynamic factor (kinetic buffering) / Vdc_min dyn_factor
Vdc_max controller speed threshold / Vdc_max n_thresh
Vdc controller proportional gain / Vdc_ctrl Kp
Vdc controller integral time / Vdc_ctrl Tn
Vdc controller rate time / Vdc_ctrl t_rate
Vdc_min controller time threshold / Vdc_min t_thresh
Vdc_min controller response (kinetic buffering) / Vdc_min response
Vdc_min controller speed threshold / Vdc_min n_thresh
Bypass dead time / Bypass t_dead
Flying restart configuration / Fly restart config
Flying restart maximum frequency for the inhibited direction / FlyRes f_max dir
Vdc controller or Vdc monitoring configuration (U/f) / Vdc_ctr config U/f
Vdc controller configuration / Vdc ctrl config
Vdc_max controller dynamic factor (U/f) / Vdc_max dyn_factor
Vdc_max controller time threshold (U/f) / Vdc_max t_thresh
Vdc_min controller switch-in level (kinetic buffering) (U/f) / Vdc_min on_level
Vdc_min controller dynamic factor (kinetic buffering) (U/f) / Vdc_min dyn_factor
SINAMICS G130/G150