Power-Inline Usage-Threshold - Allied Telesis AT-IX5-28GPX Manual

High availability, high power video surveillance poe switch
Hide thumbs Also See for AT-IX5-28GPX:
Table of Contents

Advertisement

P
E
C
OWER OVER
THERNET
OMMANDS
-
-
POWER
INLINE USAGE
THRESHOLD

power-inline usage-threshold

Overview
This command sets the level at which the Power Sourcing Equipment (PSE) will
issue a message that the power supplied to all Powered Devices (PDs) has reached
a critical level of the nominal power rating for the PSE. The level is set as a
percentage of total available power.
The no variant of this command resets the notification usage-threshold to the
default (80% of the nominal power rating of the PSE).
Syntax
power-inline usage-threshold <1-99>
no power-inline usage-threshold
Default
The default power usage threshold is 80% of the nominal power rating of the PSE.
Mode
Global Configuration
Usage
Use the
SNMP notification is sent when the usage-threshold, as configured in the example,
is exceeded.
Examples
To generate SNMP notifications when power supplied exceeds 70% of the nominal
PSE power, use the following commands:
awplus#
awplus(config)#
awplus(config)#
To reset the notification threshold to the default (80% of the nominal PSE power
rating), use the following commands:
awplus#
awplus(config)#
Validation
show power-inline interface
Commands
show running-config power-inline
Related
snmp-server enable trap
Commands
574
Command Reference for AT-IX5-28GPX High Availability, High Power Video Surveillance PoE Switch
Parameter
<1-99>
snmp-server enable trap
configure terminal
snmp-server enable trap power-inline
power-inline usage-threshold 70
configure terminal
no power-inline usage-threshold
AlliedWare Plus™ Operating System - Version 5.4.5-0.x
Description
The usage-threshold percentage configured with this
command.
command to configure SNMP notification. An
C613-50057-01 REV A

Advertisement