VLAN C
OMMANDS
-
(
SWITCHPORT VLAN
STACKING
DOUBLE TAGGING

switchport vlan-stacking (double tagging)

Overview
Use this command to enable VLAN stacking on a port and set it to be a
customer-edge-port or provider-port. This is sometimes referred to as VLAN
double-tagging, nested VLANs, or Q in Q.
Use no parameter with this command to disable VLAN stacking on an interface.
Syntax
switchport vlan-stacking {customer-edge-port|provider-port}
no switchport vlan-stacking
Default
By default, ports are not VLAN stacking ports.
Mode
Interface Configuration
Usage
Use VLAN stacking to separate traffic from different customers to that they can be
managed over a provider network
Traffic with an extra VLAN header added by VLAN stacking cannot be routed.
Example
awplus#
awplus(config)#
awplus(config-if)#
C613-50057-01 REV A
Command Reference for AT-IX5-28GPX High Availability, High Power Video Surveillance PoE Switch
)
Parameter
customer-edge-port
provider-port
configure terminal
interface port1.0.2
AlliedWare Plus™ Operating System - Version 5.4.5-0.x
Description
Set the port to be a customer edge port. This port must
already be in access mode.
Set the port to be a provider port. This port must already
be in trunk mode.
switchport vlan-stacking customer-edge-port
445