Show Power-Inline Interface Detail - Allied Telesis AT-IX5-28GPX Manual

High availability, high power video surveillance poe switch
Hide thumbs Also See for AT-IX5-28GPX:
Table of Contents

Advertisement

P
E
C
OWER OVER
THERNET
OMMANDS
-
SHOW POWER
INLINE INTERFACE DETAIL

show power-inline interface detail

Overview
This command displays detailed information for specified Power over Ethernet
(PoE) port(s) on the Power Sourcing Equipment (PSE).
For information on filtering and saving command output, see "Controlling "show"
Command Output" in the
and Configuration
Syntax
show power-inline interface [<port-list>] detail
Mode
User Exec and Privileged Exec
Usage
To show detailed PoE information for all ports on the PSE, do not specify any ports.
The power allocated to each port is listed in the Power allocated row, and is
limited by the maximum power per Powered Device (PD) class, or a user
configured power limit.
Example
To display detailed PoE port specific information for the port range 1.0.1 to
1.0.2, use the following command:
awplus#
584
Command Reference for AT-IX5-28GPX High Availability, High Power Video Surveillance PoE Switch
Guide.
Parameter
Description
Enter the PoE port(s) to display the PoE port specific information.
<port-list>
show power-inline interface port1.0.1-port1.0.2 detail
AlliedWare Plus™ Operating System - Version 5.4.5-0.x
"Getting Started with AlliedWare Plus" Feature Overview