Agency Compliance Safety Compliance 120 Volts 240 Volts (North America) 230 Volts (Europe only) Voltage UL Listed/CSA Certified Cord Set Minimum 18 AWG; type SVT or SJT three conductor cord Maximum length of 15 feet Parallel blade, grounding type attachment plug rated 15A, 125V UL Listed/CSA Certified Cord Set Minimum 18 AWG;...
AT-FH800 Series Installation Guide Making a Connection via an MDI-X Station Port Connecting to the Stack's Backplane Figure 3 Connecting to the Backplane...
Page 16
Installation Making a Connection via the MDI Daisy-Chain Port...
Page 17
AT-FH800 Series Installation Guide 10Base-T Cascade Rule A maximum of four hubs/repeaters can be cascaded within the same 10Base-T collision domain Figure 4 10Base-T Cascade Configuration...
Page 18
Installation 10Base-T Cascade Rule A maximum of four hubs/repeaters can be cascaded within the same 10Base-T collision domain Figure 5 100Base-TX Cascade Configuration...
AT-FH800 Series Installation Guide Using an Optional Module Installing an Optional Module...
Page 20
Installation Using the Agent Module (AT-FH805u) Using the Switch Module (AT-FH806u) AT-FH812u and AT-FH824u User’s Guide Figure 6 Agent Module Front Panel Figure 7 Switch Module Front Panel...
Page 21
Using the 100Base-FX Module (AT-FH807u) Using the 100Base-TX Module (AT-FH808u) AT-FH800 Series Installation Guide Figure 8 100Base-FX Module Front Panel Figure 9 100Base-TX Module Front Panel...
Page 23
Verifying Port Status Power Switch Segment LEDs (10 Mbps/100 Mbps) Activity Collision Ports LEDs (1-12/24) Yellow = 10 Mbps, Green = 100 Mbps Link/Partition Media Module LEDs Full/Half Collision Activity Link 100M Agent Module LEDs Active Figure 10 Port LEDs Table 1 LEDs State Indication...
Page 24
Installation Verifying System Operation...
Troubleshooting Cabling Verification Network Adapter Verification RJ-45 Port and Cable Assignments Figure 11 RJ-45 Connector...
Page 27
Table 2 Port Assignments Per Pin Assignment (Station ports 1-12/24 MDI-X) Input Receive Data + Input Receive Data - Output Transmit Data + Output Transmit Data - 4, 5, 7, 8 Not Used RJ45 PIN TD + TD - RD + Not Used Not Used RD -...
Appendix A Technical Specifications Base Unit Access Method Standards Conformance Communication Rate Media Supported Number of Ports Stackable Expansion Indicator Panel Dimensions Weight Input Power Power Consumption Heat Dissipation Standard Operating Temperature Humidity Certification Emissions Immunity Safety CSMA/CD, 10 Mbps or 100 Mbps IEEE 802.3 10Base-T, IEEE 802.3u 100Base-TX 10 Mbps or 100 Mbps 10Base-T 100 Ohm Category 3,4,5 UTP/STP, 100Base-TX 100...
Technical Specifications Network Criteria Hub-to-Workstation Distance Inter-hub Distance Total Network Span Single Hub Two-hub Chain 1. When cascading a dual-speed hub to another dual-speed hub or to a 100 Mbps hub, the cascade is AT-FH805u Agent Module System Configuration Management Agent RMON 4, 5, 7, 8 5 meters = 16 feet, 100 meters = 328 feet,...
Page 31
AT-FH806u Switch Module Network Bridging Function Address Table Queue Buffer Address Resolution Filtering Rate Forwarding Rate AT-FH807u Uplink 100Base-FX Module Access Method Standards Conformance Communication Rate Communication Mode Media Supported Number of Ports Indicator Panel AT-FH808u Uplink 10Base-T/100Base-TX Module Access Method Standards Conformance Communication Rate Communication Mode...