Log Permanent (Filter) - Allied Telesis AT-IX5-28GPX Manual

High availability, high power video surveillance poe switch
Hide thumbs Also See for AT-IX5-28GPX:
Table of Contents

Advertisement

L
C
OGGING
OMMANDS
(
)
LOG PERMANENT
FILTER

log permanent (filter)

Overview
This command creates a filter to select messages to be sent to the permanent log.
Selection can be based on the priority/ severity of the message, the program that
generated the message, the logging facility used, a sub-string within the message
or a combination of some or all of these.
The no variant of this command removes the corresponding filter, so that the
specified messages are no longer sent to the permanent log.
Syntax
log permanent [level <level>] [program <program-name>]
[facility <facility>] [msgtext <text-string>]
no log permanent [level <level>] [program <program-name>]
[facility <facility>] [msgtext <text-string>]
Parameter
Description
Filter messages sent to the permanent log by severity level.
level
The minimum severity of message to send. The level can be specified as one of the following
<level>
numbers or level names, where 0 is the highest severity and 7 is the lowest severity:
0|emergencies
1|alerts
2|critical
3|errors
4|warnings
5|notices
6|informational
7|debugging
Filter messages by program. Include messages from a specified program.
program
C613-50057-01 REV A
Command Reference for AT-IX5-28GPX High Availability, High Power Video Surveillance PoE Switch
System is unusable
Action must be taken immediately
Critical conditions
Error conditions
Warning conditions
Normal, but significant, conditions
Informational messages
Debug-level messages
AlliedWare Plus™ Operating System - Version 5.4.5-0.x