U
A
C
SER
CCESS
OMMANDS
-
-
SECURITY
PASSWORD REJECT
EXPIRED

security-password reject-expired-pwd

Overview
This command specifies whether or not a user is allowed to login with an expired
password. Users with expired passwords are rejected at login if this functionality is
enabled. Users then have to contact the Network Administrator to change their
password.
CAUTION
again if the security-password reject-expired-pwd command has been executed. You
will have to reboot the device with a default configuration file, or load an earlier
software version that does not have the security password feature.
We recommend you never have the command line "security-password
reject-expired-pwd" in a default config file.
Note that when the reject-expired-pwd functionality is disabled and a user logs on
with an expired password, if the forced-change feature is enabled with
security-password forced-change
password during login depending on the password lifetime specified by the
security-password lifetime
The no security-password reject-expired-pwd command disables the
reject-expired-pwd feature.
Syntax
security-password reject-expired-pwd
no security-password reject-expired-pwd
Default
The reject-expired-pwd feature is disabled by default.
Mode
Global Configuration
Example
To configure the system to reject users with an expired password, use the
command:
awplus#
awplus(config)#
Validation
show running-config security-password
Commands
show security-password configuration
Related
security-password history
Commands
security-password forced-change
security-password lifetime
security-password minimum-categories
security-password minimum-length
security-password warning
show security-password user
100
Command Reference for AT-IX5-28GPX High Availability, High Power Video Surveillance PoE Switch
-
PWD
: Once all users' passwords are expired you are unable to login to the device
command.
configure terminal
security-password reject-expired-pwd
AlliedWare Plus™ Operating System - Version 5.4.5-0.x
command, a user may have to change the
C613-50057-01 REV A