S
C
WITCHING
OMMANDS
-
-
LOOP
PROTECTION ACTION
DELAY

loop-protection action-delay-time

Overview
Use this command to sets the loop protection action delay time for an interface to
specified values in seconds. The action delay time specifies the waiting period for
the action.
Use the no variant of this command to reset the loop protection action delay time
for an interface to default.
Syntax
loop-protection action-delay-time <0-86400>
no loop-protection action
Default
Action delay timer is disabled by default.
Mode
Interface Configuration
Example
To configure a loop protection action delay time of 10 seconds, use the commands:
awplus#
awplus(config)#
awplus(config-if)#
To reset the Loop Protection action delay time to default, use the commands:
awplus#
awplus(config)#
awplus(config-if)#
Related
show loop-protection
Commands
366
Command Reference for AT-IX5-28GPX High Availability, High Power Video Surveillance PoE Switch
-
TIME
Parameter
Description
Time in seconds; 0 means action delay timer is disabled.
<0-86400>
configure terminal
interface port1.0.4
configure terminal
interface port1.1.4
AlliedWare Plus™ Operating System - Version 5.4.5-0.x
loop-protection action-delay-time 10
no loop-protection action-delay-time
C613-50057-01 REV A