P
E
C
OWER OVER
THERNET
OMMANDS
-
POWER
INLINE DESCRIPTION

power-inline description

Overview
This command adds a description for a Powered Device (PD) connected to a PoE
port.
The no variant of this command clears a previously entered description for a
connected PD, resetting the PD description to the default (null).
Syntax
power-inline description <pd-description>
no power-inline description
Default
No description for a connected PD is set by default.
Mode
Interface Configuration
Usage
Select a PoE port, a list of PoE ports, or a range of PoE ports with the preceding
interface (to configure)
all be PoE capable ports.
Examples
To add the description Desk Phone for a connected PD on port1.0.2, use the
following commands:
awplus#
awplus(config)#
awplus(config-if)#
To clear the description as added above for the connected PD on port1.0.2, use
the following commands:
awplus#
awplus(config)#
awplus(config-if)#
Validation
show power-inline interface
Commands
show running-config power-inline
568
Command Reference for AT-IX5-28GPX High Availability, High Power Video Surveillance PoE Switch
Parameter
<pd-description>
configure terminal
interface port1.0.2
configure terminal
interface port1.0.2
AlliedWare Plus™ Operating System - Version 5.4.5-0.x
Description
Description of the PD connected to the PoE capable port
(with a maximum 256 character string limit per PD
description).
command. If you specify a range or list of ports they must
power-inline description Desk Phone
no power-inline description