power-inline usage-threshold

Overview
This command sets the level at which the switch will issue a message that the
power supplied to all Powered Devices (PDs) has reached a critical level of the
nominal power rating for the switch. The level is set as a percentage of total
available power.
The no variant of this command resets the notification usage-threshold to the
default (80% of the nominal power rating).
power-inline usage-threshold <1-99>
Syntax
no power-inline usage-threshold
Default
The default power usage threshold is 80% of the nominal power rating
Mode
Global Configuration
Usage notes
Use the
SNMP notification is sent when the usage-threshold, as configured in the example,
is exceeded.
Examples
To generate SNMP notifications when power supplied exceeds 70% of the nominal
power rating, use the following commands:
awplus#
awplus(config)#
awplus(config)#
To reset the notification threshold to the default (80% of the nominal power
rating), use the following commands:
awplus#
awplus(config)#
Related
snmp-server enable trap
commands
show power-inline interface
show running-config
Command
Version 5.4.8-0.2: added to x550 series products
changes
C613-50631-01 Rev A
Parameter
<1-99>
snmp-server enable trap
configure terminal
snmp-server enable trap power-inline
power-inline usage-threshold 70
configure terminal
no power-inline usage-threshold
power-inline
Command Reference for IE340 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
Description
The usage-threshold percentage configured with this
command.
command to configure SNMP notification. An