Power-Inline Priority - Allied Telesis AT-IX5-28GPX Manual

High availability, high power video surveillance poe switch
Hide thumbs Also See for AT-IX5-28GPX:
Table of Contents

Advertisement

P
E
C
OWER OVER
THERNET
OMMANDS
-
POWER
INLINE PRIORITY

power-inline priority

Overview
This command sets the Power over Ethernet (PoE) priority level of a PoE port to one
of three available priority levels:
The no variant of this command restores the PoE port priority to the default (low).
Syntax
power-inline priority {low|high|critical}
no power-inline priority
Default
The default priority is low for all PoE ports on the Power Sourcing Equipment (PSE).
Mode
Interface Configuration
Usage
This command is supported on all PoE capable ports, whether operating as a
stand-alone switch, or within a VCStack.
Select a PoE port, a list of PoE ports, or a range of PoE ports with the preceding
interface (to configure)
all be PoE capable ports.
PoE ports with higher priorities are given power before PoE ports with lower
priorities. If the priorities for two PoE ports are the same then the lower numbered
PoE port is given power before the higher numbered PoE port.
See the
about PoE priority.
572
Command Reference for AT-IX5-28GPX High Availability, High Power Video Surveillance PoE Switch
low
high
critical
Parameter
low
high
critical
PoE Feature Overview and Configuration Guide
AlliedWare Plus™ Operating System - Version 5.4.5-0.x
Description
The lowest priority for a PoE enabled port (default). PoE ports
set to low only receive power if all the PoE ports assigned to
the other two levels are already receiving power.
The second highest priority for a PoE enabled port. PoE ports
set to high receive power only if all the ports set to
critical are already receiving power.
The highest priority for a PoE enabled port. PoE ports set to
critical are guaranteed power before any ports assigned
to the other two priority levels. Ports assigned to the other
priority levels receive power only if all Critical ports are
receiving power.
command. If you specify a range or list of ports they must
for further information
C613-50057-01 REV A

Advertisement

Table of Contents
loading