8XC196K x , J x , CA USER'S MANUAL
.
Symbol
T
READY Hold after CLKOUT Low
CLYX
Minimum hold time is typically 0 ns. If maximum specification is exceeded, additional wait
states will occur.
T
Address Valid to READY Setup
AVYV
Maximum time the memory system has to assert READY after the device outputs the address
to guarantee that at least one wait state will occur.
CLKOUT
ALE
READY
T
RD#
Address Out
AD15:0
WR#
AD15:0
Address Out
15-16
Table 15-2. READY Signal Timing Definitions
T
CLYX
(MIN)
T
CLYX
(MAX)
AVYV
Figure 15-7. READY Timing Diagram
Definition
Data
Data Out
Address
A3076-01