AUGER FEEDBACK
Use this screen to set the feedback parameters.
E
F
NABLE
EEDBACK
G
AP
S
R
TEP
ATE
U l t i m a S V
Enables/disables feedback adjustments. If the feedback function is dis-
abled, the filler PLC will ignore any feedback signals sent from the
checkweigher.
Sets the number of required fill cycles to be completed before any
weight feedback adjustments will be made by the filler PLC. Accept-
able values range from 1 to 99, where a value of 1 will allow feedback
adjustments after every fill cycle. A value of 2 will only allow feed-
back adjustments after every other fill cycle.
Sets the rate at which incremental adjustment steps are made to the
current auger turns setting. Acceptable values range from 1 to 9, where
a value of 1 results in less frequent adjustment steps and a value of 9
results in more frequent adjustment steps.